Cabinet · base-station · data-room · battery cooling · 300 W–45 kW
Industrial HVAC & Enclosure Cooling
Cabinet cooling, base-station cooling, data-room cooling and battery-storage cooling for telecom, industrial and power-grid sites — from 300 W DC cabinet units and heat exchangers to 20 kW container air conditioners, 45 kW in-row units and liquid-cooling units for battery shelters.
Cabinet Air Conditioners — AC Type
For telecom and industrial outdoor cabinets on AC power. High-efficiency rotary compressor, RS485 port for remote monitoring, high protection level for outdoor use and a wide operating range for hot and cold regions. R134a refrigerant; heating and dehumidification options. 600 W–5 kW.
- Power 1~220 VAC ±15% · 50 Hz
- Operating range −40 °C to +55 °C · IP55 · R134a
- Rated condition L35 °C / L35 °C
| Model | Cooling | Heating | W×H×D (mm) |
|---|---|---|---|
| A06HA1E | 600 W | 500 W | 315×546×175 |
| A10HA1E | 1000 W | 1000 W | 446×746×200 |
| A15HA1E | 1500 W | 1000 W | 446×746×200 |
| A20HA1E | 2000 W | 1000 W | 446×746×200 |
| A30HA1E | 3000 W | 1500 W | 485×1150×250 |
| A40HA1E | 4000 W | 1500 W | 485×1150×250 |
| A50HA1E | 5000 W | 3000 W | 600×1300×320 |
Cabinet Air Conditioners — DC Type
For telecom and industrial outdoor cabinets on DC power. High-efficiency DC-inverter compressor, RS485 port for remote monitoring, high protection level for outdoor use and a wide operating range. R134a refrigerant. 300 W–4 kW.
- Power DC 48 V ±20%
- Operating range −40 °C to +55 °C · IP55 · R134a
- Heating Optional
- Rated condition L35 °C / L35 °C
| Model | Cooling | W×H×D (mm) |
|---|---|---|
| A03NA0E | 300 W | 315×320×140 |
| A06NA0E | 600 W | 315×546×175 |
| A10NA0E | 1000 W | 446×746×200 |
| A15NA0E | 1500 W | 446×746×200 |
| A20NA0E | 2000 W | 446×746×200 |
| A30NA0E | 3000 W | 485×1150×250 |
| A40NA0E | 4000 W | 485×1150×250 |
Air Conditioner + Heat Exchanger Combined
Dual-system cooling for telecom outdoor cabinets: a compressor cooling unit plus a siphon heat-pipe exchanger, switching automatically for energy-saving operation. RS485 port for remote monitoring and a wide operating range. R134a refrigerant, IP55. 1.5–3 kW.
- Power — HA4E DC 48 V ±20% + 1~230 VAC ±15% · 50 Hz
- Power — HA0E DC 48 V ±20%
- Operating range −40 °C to +55 °C · IP55 · R134a
- Heating Optional
| Model (AC+DC / DC) | Cooling | Heat exchange | W×H×D (mm) |
|---|---|---|---|
| AE15HA4E / AE15HA0E | 1500 W | 60 W/K | 446×746×240 |
| AE20HA4E / AE20HA0E | 2000 W | 80 W/K | 446×746×240 |
| AE25HA4E / AE25HA0E | 2500 W | 100 W/K | 446×746×260 |
| AE30HA4E / AE30HA0E | 3000 W | 120 W/K | 485×1150×300 |
Cabinet Heat Exchangers — DC Type
For telecom and industrial outdoor cabinets on DC power. High-efficiency DC centrifugal fan, RS485 port for remote monitoring, high protection level for outdoor use, a wide operating range and a maintenance-free design; heater optional. 25–260 W/K.
- Power DC 48 V ±20%
- Operating range −40 °C to +60 °C · IP55
- Heat-exchange core Air-to-air aluminium plate
- Heating Optional
| Model | Heat exchange | W×H×D (mm) |
|---|---|---|
| H02NA0E | 25 W/K | 270×420×165 |
| H08NA0E | 80 W/K | 400×900×145 |
| H10NA0E | 100 W/K | 412×990×192 |
| H12NA0E | 120 W/K | 412×990×192 |
| H15NA0E | 150 W/K | 518×1246×240 |
| H18NA0E | 180 W/K | 518×1246×240 |
| H26NA0E | 260 W/K | 620×1300×240 |
BTS Split Air Conditioner — DC
For telecom base stations and outdoor shelters on DC 48 V power. High-efficiency DC-inverter compressor, RS485 port for remote monitoring, split design and a wide operating range. R134a refrigerant. 4 kW.
- A40NA0F 4000 W cooling · DC 48 V ±20% · heating N/A
- Dimensions Indoor 950×340×215 · outdoor 730×524×292 mm
- Mounting Wall-mounted
- Operating range −40 °C to +55 °C · IP55 · R134a
- Rated condition L35 °C / L35 °C
BTS Air Conditioner + Free Cooling
Dual-system cooling for telecom base stations and outdoor shelters: active compressor cooling plus fresh-air free cooling, switching automatically for energy-saving operation. DC-inverter compressor, EC fan and RS485 port; an integrated dust sensor stops fresh-air operation in dusty conditions, an integrated humidity sensor prevents excessive internal humidity, and the intake filter is built in. 12.5–15 kW.
- Power 3~380 V ±15% · 50 Hz
- Build Fresh-air damper (auto) · G4 filter · wall-mounted
- Dimensions W800×H2100×D705 mm
- Operating range −40 °C to +45 °C · R410a · heating optional
| Model | Cooling (L27 °C / L35 °C) | Air flow |
|---|---|---|
| WAF125NA5S | 12.5 kW | 3500 m³/h |
| WAF150NA5S | 15.0 kW | 3800 m³/h |
In-Row Air Conditioners — DX Type
Data-room cooling, refrigerant direct-expansion. DC-inverter compressor, EC fan and electronic expansion valve (EEV); RS485 port for remote monitoring and a wide operating range. Humidification, dehumidification and heating optional. 12.5–45 kW.
- Power 3~380 V ±15% · 50 Hz
- Operating range −30 °C to +45 °C · R410a
- Interface · filter LCD touch screen · G4
- Heating Optional
| Model | Total cooling | Sensible | EER | Air flow (m³/h) | Humidification | Indoor W×D×H (mm) |
|---|---|---|---|---|---|---|
| CDA12HA5E | 12.5 kW | 11.5 kW | 3.5 | 3000 | 3 kg/h | 300×1200×2000 |
| CDA25HA5E | 25 kW | 22.0 kW | 3.3 | 5000 | 3 kg/h | 600×1200×2000 |
| CDA35HA5E | 35 kW | 32.0 kW | 3.4 | 7000 | 3 kg/h | 600×1200×2000 |
| CDA45HA5E | 45 kW | 40.5 kW | 3.3 | 9500 | 6 kg/h | 600×1200×2000 |
In-Row Air Conditioners — CW Type
Data-room cooling, chilled-water type. 2-way electric proportional control valve and EC fan; suits 18 °C water supply for more energy saving; RS485 port for remote monitoring. Humidification, dehumidification and heating optional. 12.5–45 kW.
- Water supply 7–18 °C
- Interface · filter LCD touch screen · G4
- Heating Optional
| Model | Total cooling | Sensible | EER | Air flow (m³/h) | Humidification | Power | Indoor W×D×H (mm) |
|---|---|---|---|---|---|---|---|
| CWA12HA5E | 12.5 kW | 11.8 kW | 3.5 | 2800 | 3 kg/h | 1~230 V | 300×1200×2000 |
| CWA25HA5E | 25 kW | 23.0 kW | 3.3 | 4800 | 3 kg/h | 1~230 V | 600×1200×2000 |
| CWA35HA5E | 35 kW | 33.0 kW | 3.4 | 7000 | 3 kg/h | 3~380 V | 600×1200×2000 |
| CWA45HA5E | 45 kW | 41.0 kW | 3.3 | 9000 | 6 kg/h | 3~380 V | 600×1200×2000 |
Container Air Conditioners — Embedded Mounting
For industrial and battery energy-storage shelters, semi-embedded mounting. High-efficiency rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. AF models use a DC-inverter compressor. 3–20 kW.
- Protection IP55
- Operating range −40 °C to +45 °C · R410a (A30HC1E: −40 °C to +55 °C · R134a)
| Model | Cooling | Heating | Power | Rated condition | W×H×D (mm) |
|---|---|---|---|---|---|
| A30HC1E | 3.0 kW | 2.0 kW | 1~230 V | L35 / L35 °C | 500×1300×250 |
| A50HC1E | 5.0 kW | 3.0 kW | 1~230 V | L35 / L35 °C | 600×1300×320 |
| A75HC1E | 7.5 kW | 3.0 kW | 1~230 V | L35 / L35 °C | 660×1600×400 |
| A100HC1E | 10.0 kW | 6.0 kW | 1~230 V | L35 / L35 °C | 660×1600×400 |
| A125HC5E / AF125HC5E | 12.5 kW | 6.0 kW | 3~380 V | L27 / L35 °C | 800×2100×600 |
| A150HC5E / AF150HC5E | 15.0 kW | 9.0 kW | 3~380 V | L27 / L35 °C | 800×2100×600 |
| A200HC5E / AF200HC5E | 20.0 kW | 9.0 kW | 3~380 V | L27 / L35 °C | 800×2100×600 |
Container Air Conditioners — Side Mounting
For industrial and battery energy-storage shelters, side (wall) mounting. High-efficiency rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. AF models use a DC-inverter compressor. 7.5–20 kW.
- Operating range −40 °C to +45 °C · IP55 · R410a
| Model | Cooling | Heating | Power | Rated condition | W×H×D (mm) |
|---|---|---|---|---|---|
| A75HC1S | 7.5 kW | 3.0 kW | 1~230 V | L35 / L35 °C | 660×1600×400 |
| A10HC1S | 10.0 kW | 6.0 kW | 1~230 V | L35 / L35 °C | 660×1600×400 |
| A120HC1E | 12.0 kW | 6.0 kW | 1~230 V | L35 / L35 °C | 660×1600×400 |
| A125HC5S / AF125HC5S | 12.5 kW | 6.0 kW | 3~380 V | L27 / L35 °C | 800×2100×705 |
| A150HC5S | 15.0 kW | 9.0 kW | 3~380 V | L27 / L35 °C | 800×2100×705 |
| AF150HC5S | 15.0 kW | 6.0 kW | 3~380 V | L27 / L35 °C | 800×2100×703 |
| A200HC5S / AF200HC5S | 20.0 kW | 9.0 kW | 3~380 V | L27 / L35 °C | 800×2100×705 |
Container Air Conditioners — Top Mounting
For industrial and battery energy-storage shelters, roof mounting. High-efficiency DC-inverter rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. 3–5 kW and 12.5–20 kW.
- Operating range −40 °C to +45 °C · IP55 · R410a
| Model | Cooling | Heating | Air flow | Power | Rated condition | W×D×H (mm) |
|---|---|---|---|---|---|---|
| AF30HC1T | 3.0 kW | 1.5 kW | 1000 m³/h | 1~230 V | L25 / L35 °C | 870×1000×350 |
| AF40HC1T | 4.0 kW | 2.0 kW | 2000 m³/h | 1~230 V | L25 / L35 °C | 870×1000×350 |
| AF50HC1T | 5.0 kW | 2.0 kW | 2000 m³/h | 1~230 V | L25 / L35 °C | 870×1000×350 |
| AF125HC5T | 12.5 kW | 6.0 kW | 3600 m³/h | 3~380 V | L27 / L35 °C | 1200×1780×603 |
| AF150HC5T | 15.0 kW | 9.0 kW | 5000 m³/h | 3~380 V | L27 / L35 °C | 1200×1780×603 |
| AF200HC5T | 20.0 kW | 9.0 kW | 5500 m³/h | 3~380 V | L27 / L35 °C | 1200×1780×603 |
Liquid Cooling Units
For battery energy-storage shelters with liquid cooling. High-efficiency inverter compressor, RS485/CAN port and environment-friendly refrigerant; a wide operating range for many regions; liquid heating, optional shelter dehumidification and an ambient intake filter. LF models use a DC-inverter compressor. 3–8 kW.
- Power 1~230 V ±15% · 50/60 Hz
- Rated condition W 18 °C / A 35 °C
- Operating range −30 °C to +55 °C · electrics IP55 · R134a
- Pipe connection NW26 quick connectors
| Model | Cooling | Heating | Water flow | Mounting | Dehumidification | W×H×D (mm) |
|---|---|---|---|---|---|---|
| LF30HA1T | 3.0 kW | 1.0 kW | 25 L/min | Top | Optional | 702×280×932 |
| LF50HA1T | 5.0 kW | 2.0 kW | 45 L/min | Top | Optional | 702×280×932 |
| LF30HA1B | 3.0 kW | 1.0 kW | 25 L/min | Vertical | N/A | 275×800×1100 |
| LF50HA1B | 5.0 kW | 2.0 kW | 45 L/min | Vertical | N/A | 275×800×1100 |
| LF80HA1B | 8.0 kW | 2.0 kW | 50 L/min | Vertical | N/A | 275×1040×1150 |
Standards & certifications
Typical applications
- Telecom cabinets & base stations
- Industrial automation cabinets
- Power-grid equipment
- Data rooms
- Battery energy-storage shelters
Representative selection — the full range and exact specifications are confirmed on quote. Custom configurations available.
Built and certified to international standards
- UL
- CE
- NEMA 1–13
- IP67
- IP68
- ATEX
- IECEx
- SAA
- RoHS
- UL 94 V-0
- ISO 9001
- CCC
- IK10
- UL
- CE
- NEMA 1–13
- IP67
- IP68
- ATEX
- IECEx
- SAA
- RoHS
- UL 94 V-0
- ISO 9001
- CCC
- IK10
Tell us the job — we’ll spec and quote it