Cabinet · base-station · data-room · battery cooling · 300 W–45 kW

Industrial HVAC & Enclosure Cooling

Cabinet cooling, base-station cooling, data-room cooling and battery-storage cooling for telecom, industrial and power-grid sites — from 300 W DC cabinet units and heat exchangers to 20 kW container air conditioners, 45 kW in-row units and liquid-cooling units for battery shelters.

Industrial HVAC & Enclosure Cooling
Cabinet Air Conditioners — AC Type

Cabinet Air Conditioners — AC Type

For telecom and industrial outdoor cabinets on AC power. High-efficiency rotary compressor, RS485 port for remote monitoring, high protection level for outdoor use and a wide operating range for hot and cold regions. R134a refrigerant; heating and dehumidification options. 600 W–5 kW.

  • Power 1~220 VAC ±15% · 50 Hz
  • Operating range −40 °C to +55 °C · IP55 · R134a
  • Rated condition L35 °C / L35 °C
ModelCoolingHeatingW×H×D (mm)
A06HA1E600 W500 W315×546×175
A10HA1E1000 W1000 W446×746×200
A15HA1E1500 W1000 W446×746×200
A20HA1E2000 W1000 W446×746×200
A30HA1E3000 W1500 W485×1150×250
A40HA1E4000 W1500 W485×1150×250
A50HA1E5000 W3000 W600×1300×320
Enquire
Cabinet Air Conditioners — DC Type

Cabinet Air Conditioners — DC Type

For telecom and industrial outdoor cabinets on DC power. High-efficiency DC-inverter compressor, RS485 port for remote monitoring, high protection level for outdoor use and a wide operating range. R134a refrigerant. 300 W–4 kW.

  • Power DC 48 V ±20%
  • Operating range −40 °C to +55 °C · IP55 · R134a
  • Heating Optional
  • Rated condition L35 °C / L35 °C
ModelCoolingW×H×D (mm)
A03NA0E300 W315×320×140
A06NA0E600 W315×546×175
A10NA0E1000 W446×746×200
A15NA0E1500 W446×746×200
A20NA0E2000 W446×746×200
A30NA0E3000 W485×1150×250
A40NA0E4000 W485×1150×250
Enquire
Air Conditioner + Heat Exchanger Combined

Air Conditioner + Heat Exchanger Combined

Dual-system cooling for telecom outdoor cabinets: a compressor cooling unit plus a siphon heat-pipe exchanger, switching automatically for energy-saving operation. RS485 port for remote monitoring and a wide operating range. R134a refrigerant, IP55. 1.5–3 kW.

  • Power — HA4E DC 48 V ±20% + 1~230 VAC ±15% · 50 Hz
  • Power — HA0E DC 48 V ±20%
  • Operating range −40 °C to +55 °C · IP55 · R134a
  • Heating Optional
Model (AC+DC / DC)CoolingHeat exchangeW×H×D (mm)
AE15HA4E / AE15HA0E1500 W60 W/K446×746×240
AE20HA4E / AE20HA0E2000 W80 W/K446×746×240
AE25HA4E / AE25HA0E2500 W100 W/K446×746×260
AE30HA4E / AE30HA0E3000 W120 W/K485×1150×300
Enquire
Cabinet Heat Exchangers — DC Type

Cabinet Heat Exchangers — DC Type

For telecom and industrial outdoor cabinets on DC power. High-efficiency DC centrifugal fan, RS485 port for remote monitoring, high protection level for outdoor use, a wide operating range and a maintenance-free design; heater optional. 25–260 W/K.

  • Power DC 48 V ±20%
  • Operating range −40 °C to +60 °C · IP55
  • Heat-exchange core Air-to-air aluminium plate
  • Heating Optional
ModelHeat exchangeW×H×D (mm)
H02NA0E25 W/K270×420×165
H08NA0E80 W/K400×900×145
H10NA0E100 W/K412×990×192
H12NA0E120 W/K412×990×192
H15NA0E150 W/K518×1246×240
H18NA0E180 W/K518×1246×240
H26NA0E260 W/K620×1300×240
Enquire
BTS Split Air Conditioner — DC

BTS Split Air Conditioner — DC

For telecom base stations and outdoor shelters on DC 48 V power. High-efficiency DC-inverter compressor, RS485 port for remote monitoring, split design and a wide operating range. R134a refrigerant. 4 kW.

  • A40NA0F 4000 W cooling · DC 48 V ±20% · heating N/A
  • Dimensions Indoor 950×340×215 · outdoor 730×524×292 mm
  • Mounting Wall-mounted
  • Operating range −40 °C to +55 °C · IP55 · R134a
  • Rated condition L35 °C / L35 °C
Enquire
BTS Air Conditioner + Free Cooling

BTS Air Conditioner + Free Cooling

Dual-system cooling for telecom base stations and outdoor shelters: active compressor cooling plus fresh-air free cooling, switching automatically for energy-saving operation. DC-inverter compressor, EC fan and RS485 port; an integrated dust sensor stops fresh-air operation in dusty conditions, an integrated humidity sensor prevents excessive internal humidity, and the intake filter is built in. 12.5–15 kW.

  • Power 3~380 V ±15% · 50 Hz
  • Build Fresh-air damper (auto) · G4 filter · wall-mounted
  • Dimensions W800×H2100×D705 mm
  • Operating range −40 °C to +45 °C · R410a · heating optional
ModelCooling (L27 °C / L35 °C)Air flow
WAF125NA5S12.5 kW3500 m³/h
WAF150NA5S15.0 kW3800 m³/h
Enquire
In-Row Air Conditioners — DX Type

In-Row Air Conditioners — DX Type

Data-room cooling, refrigerant direct-expansion. DC-inverter compressor, EC fan and electronic expansion valve (EEV); RS485 port for remote monitoring and a wide operating range. Humidification, dehumidification and heating optional. 12.5–45 kW.

  • Power 3~380 V ±15% · 50 Hz
  • Operating range −30 °C to +45 °C · R410a
  • Interface · filter LCD touch screen · G4
  • Heating Optional
Enquire
ModelTotal coolingSensibleEERAir flow (m³/h)HumidificationIndoor W×D×H (mm)
CDA12HA5E12.5 kW11.5 kW3.530003 kg/h300×1200×2000
CDA25HA5E25 kW22.0 kW3.350003 kg/h600×1200×2000
CDA35HA5E35 kW32.0 kW3.470003 kg/h600×1200×2000
CDA45HA5E45 kW40.5 kW3.395006 kg/h600×1200×2000
In-Row Air Conditioners — CW Type

In-Row Air Conditioners — CW Type

Data-room cooling, chilled-water type. 2-way electric proportional control valve and EC fan; suits 18 °C water supply for more energy saving; RS485 port for remote monitoring. Humidification, dehumidification and heating optional. 12.5–45 kW.

  • Water supply 7–18 °C
  • Interface · filter LCD touch screen · G4
  • Heating Optional
Enquire
ModelTotal coolingSensibleEERAir flow (m³/h)HumidificationPowerIndoor W×D×H (mm)
CWA12HA5E12.5 kW11.8 kW3.528003 kg/h1~230 V300×1200×2000
CWA25HA5E25 kW23.0 kW3.348003 kg/h1~230 V600×1200×2000
CWA35HA5E35 kW33.0 kW3.470003 kg/h3~380 V600×1200×2000
CWA45HA5E45 kW41.0 kW3.390006 kg/h3~380 V600×1200×2000
Container Air Conditioners — Embedded Mounting

Container Air Conditioners — Embedded Mounting

For industrial and battery energy-storage shelters, semi-embedded mounting. High-efficiency rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. AF models use a DC-inverter compressor. 3–20 kW.

  • Protection IP55
  • Operating range −40 °C to +45 °C · R410a (A30HC1E: −40 °C to +55 °C · R134a)
Enquire
ModelCoolingHeatingPowerRated conditionW×H×D (mm)
A30HC1E3.0 kW2.0 kW1~230 VL35 / L35 °C500×1300×250
A50HC1E5.0 kW3.0 kW1~230 VL35 / L35 °C600×1300×320
A75HC1E7.5 kW3.0 kW1~230 VL35 / L35 °C660×1600×400
A100HC1E10.0 kW6.0 kW1~230 VL35 / L35 °C660×1600×400
A125HC5E / AF125HC5E12.5 kW6.0 kW3~380 VL27 / L35 °C800×2100×600
A150HC5E / AF150HC5E15.0 kW9.0 kW3~380 VL27 / L35 °C800×2100×600
A200HC5E / AF200HC5E20.0 kW9.0 kW3~380 VL27 / L35 °C800×2100×600
Container Air Conditioners — Side Mounting

Container Air Conditioners — Side Mounting

For industrial and battery energy-storage shelters, side (wall) mounting. High-efficiency rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. AF models use a DC-inverter compressor. 7.5–20 kW.

  • Operating range −40 °C to +45 °C · IP55 · R410a
Enquire
ModelCoolingHeatingPowerRated conditionW×H×D (mm)
A75HC1S7.5 kW3.0 kW1~230 VL35 / L35 °C660×1600×400
A10HC1S10.0 kW6.0 kW1~230 VL35 / L35 °C660×1600×400
A120HC1E12.0 kW6.0 kW1~230 VL35 / L35 °C660×1600×400
A125HC5S / AF125HC5S12.5 kW6.0 kW3~380 VL27 / L35 °C800×2100×705
A150HC5S15.0 kW9.0 kW3~380 VL27 / L35 °C800×2100×705
AF150HC5S15.0 kW6.0 kW3~380 VL27 / L35 °C800×2100×703
A200HC5S / AF200HC5S20.0 kW9.0 kW3~380 VL27 / L35 °C800×2100×705
Container Air Conditioners — Top Mounting

Container Air Conditioners — Top Mounting

For industrial and battery energy-storage shelters, roof mounting. High-efficiency DC-inverter rotary compressor, RS485 port and environment-friendly refrigerant; high protection level for outdoor use; heating, dehumidification and an ambient intake filter integrated. 3–5 kW and 12.5–20 kW.

  • Operating range −40 °C to +45 °C · IP55 · R410a
Enquire
ModelCoolingHeatingAir flowPowerRated conditionW×D×H (mm)
AF30HC1T3.0 kW1.5 kW1000 m³/h1~230 VL25 / L35 °C870×1000×350
AF40HC1T4.0 kW2.0 kW2000 m³/h1~230 VL25 / L35 °C870×1000×350
AF50HC1T5.0 kW2.0 kW2000 m³/h1~230 VL25 / L35 °C870×1000×350
AF125HC5T12.5 kW6.0 kW3600 m³/h3~380 VL27 / L35 °C1200×1780×603
AF150HC5T15.0 kW9.0 kW5000 m³/h3~380 VL27 / L35 °C1200×1780×603
AF200HC5T20.0 kW9.0 kW5500 m³/h3~380 VL27 / L35 °C1200×1780×603
Liquid Cooling Units

Liquid Cooling Units

For battery energy-storage shelters with liquid cooling. High-efficiency inverter compressor, RS485/CAN port and environment-friendly refrigerant; a wide operating range for many regions; liquid heating, optional shelter dehumidification and an ambient intake filter. LF models use a DC-inverter compressor. 3–8 kW.

  • Power 1~230 V ±15% · 50/60 Hz
  • Rated condition W 18 °C / A 35 °C
  • Operating range −30 °C to +55 °C · electrics IP55 · R134a
  • Pipe connection NW26 quick connectors
Enquire
ModelCoolingHeatingWater flowMountingDehumidificationW×H×D (mm)
LF30HA1T3.0 kW1.0 kW25 L/minTopOptional702×280×932
LF50HA1T5.0 kW2.0 kW45 L/minTopOptional702×280×932
LF30HA1B3.0 kW1.0 kW25 L/minVerticalN/A275×800×1100
LF50HA1B5.0 kW2.0 kW45 L/minVerticalN/A275×800×1100
LF80HA1B8.0 kW2.0 kW50 L/minVerticalN/A275×1040×1150

Standards & certifications

IP55 RS485 · CAN R134a / R410a DC 48 V & AC power DC-inverter compressors EC fans −40 °C…+60 °C

Typical applications

  • Telecom cabinets & base stations
  • Industrial automation cabinets
  • Power-grid equipment
  • Data rooms
  • Battery energy-storage shelters

Representative selection — the full range and exact specifications are confirmed on quote. Custom configurations available.

Built and certified to international standards

  • UL
  • CE
  • NEMA 1–13
  • IP67
  • IP68
  • ATEX
  • IECEx
  • SAA
  • RoHS
  • UL 94 V-0
  • ISO 9001
  • CCC
  • IK10
  • UL
  • CE
  • NEMA 1–13
  • IP67
  • IP68
  • ATEX
  • IECEx
  • SAA
  • RoHS
  • UL 94 V-0
  • ISO 9001
  • CCC
  • IK10

Tell us the job — we’ll spec and quote it

Send us your application, load and site conditions. We’ll come back with the right unit, the certifications you need and a factory-direct price.